IPIO Datasheet: Difference between revisions
Appearance
Created page with "thumb|IPIO This is a draft {| class="wikitable" |+ ! ! |- | colspan="2" |'''Communications''' |- |Interface |Ethernet |- |LAN |1-port 10/100Base-T(X) |- | colspan="2" |'''Channels''' |- |Input |4 Digital |- |Output |8 Digital |- |Dry Contact | |- |Wet Contact | |- |Pulse | |- | colspan="2" |'''Power''' |- |Input |24V |- |Consumption | |- | colspan="2" |'''Connectors''' |- |Input |1x4 plug-in screw terminal block |- |Output |1x8 plug-in screw terminal b..." |
No edit summary |
||
| (10 intermediate revisions by the same user not shown) | |||
| Line 18: | Line 18: | ||
|Input | |Input | ||
|4 Digital | |4 Digital | ||
|- | |||
|Input type | |||
|Voltage-driven digital input | |||
|- | |||
|Input interface | |||
|Optocoupler-based input stage | |||
|- | |||
|Optocoupler component isolation | |||
|5 kVrms input-to-output isolation for 1 minute | |||
|- | |- | ||
|Output | |Output | ||
|8 Digital | |8 Digital | ||
|- | |- | ||
| | |Output type | ||
| | |Solid-state sourcing voltage output | ||
|- | |||
|Output voltage | |||
|Tracks the applied field supply voltage | |||
|- | |||
|Recommended application range | |||
|12-24 VDC systems | |||
|- | |||
|Protected continuous output current | |||
|Up to 200 mA per channel | |||
|- | |||
|Output device class | |||
|G3VM-61D1 type SSR, 60 V load voltage, 500 mA element rating | |||
|- | |||
|Pulse interval | |||
|Firmware configurable | |||
|- | |||
|Derived pulse timing capability | |||
|SSR tON = 0.8 ms typ / 2.0 ms max, tOFF = 0.1 ms typ / 0.5 ms max | |||
|- | |- | ||
| | |Recommended pulse rate | ||
| | |Conservative publication candidate <= 200 Hz for low-frequency signaling | ||
|- | |- | ||
| | |Application note | ||
| | |Outputs are voltage outputs, not dry contacts. Use an external relay if dry-contact behavior or higher-power switching is required. | ||
|- | |- | ||
| colspan="2" |'''Power''' | | colspan="2" |'''Power''' | ||
|- | |- | ||
|Input | |Input | ||
| | |12-24VDC | ||
|- | |||
|Derived input current @ 12 VDC | |||
|Approximately 70 to 100 mA, excluding external output loads | |||
|- | |||
|Derived input current @ 24 VDC | |||
|Approximately 35 to 50 mA, excluding external output loads | |||
|- | |- | ||
| | |Additional current per asserted DI | ||
| | |Approximately 2.8 mA @ 12 VDC, 5.8 mA @ 24 VDC when driven from the module supply domain | ||
|- | |- | ||
| colspan="2" |'''Connectors''' | | colspan="2" |'''Connectors''' | ||
| Line 49: | Line 82: | ||
|Power | |Power | ||
|1x2 plug-in screw terminal block | |1x2 plug-in screw terminal block | ||
|- | |||
|Terminal pitch | |||
|3.5 mm | |||
|- | |- | ||
| colspan="2" |'''Leds''' | | colspan="2" |'''Leds''' | ||
| Line 64: | Line 100: | ||
| colspan="2" |'''Software''' | | colspan="2" |'''Software''' | ||
|- | |- | ||
| | |Connection | ||
| | |TCP | ||
|- | |||
|Interface | |||
|IPIO Manager | |||
|- | |||
|UAC | |||
|Username/Password <ref>IPIO has 2 default users defined, one for VIS access and one for administration.</ref> | |||
|- | |- | ||
| colspan="2" |'''General''' | | colspan="2" |'''General''' | ||
|- | |- | ||
|Dimensions | |Dimensions | ||
| | |110x83x30 mm (without rail adaptor) | ||
|- | |||
|Weight | |||
|202 g | |||
|- | |- | ||
|Package | |Package | ||
|Cardboard box | |Cardboard box (13x18x8 cm) | ||
|- | |- | ||
|Mounting | |Mounting | ||
| Line 80: | Line 125: | ||
|Certification | |Certification | ||
|CE, Rohs | |CE, Rohs | ||
|} | |} | ||
[[Category:IPIO]] | |||
==Notes== | |||
<references /> | |||
Latest revision as of 11:46, 14 May 2026

This is a draft
| Communications | |
| Interface | Ethernet |
| LAN | 1-port 10/100Base-T(X) |
| Channels | |
| Input | 4 Digital |
| Input type | Voltage-driven digital input |
| Input interface | Optocoupler-based input stage |
| Optocoupler component isolation | 5 kVrms input-to-output isolation for 1 minute |
| Output | 8 Digital |
| Output type | Solid-state sourcing voltage output |
| Output voltage | Tracks the applied field supply voltage |
| Recommended application range | 12-24 VDC systems |
| Protected continuous output current | Up to 200 mA per channel |
| Output device class | G3VM-61D1 type SSR, 60 V load voltage, 500 mA element rating |
| Pulse interval | Firmware configurable |
| Derived pulse timing capability | SSR tON = 0.8 ms typ / 2.0 ms max, tOFF = 0.1 ms typ / 0.5 ms max |
| Recommended pulse rate | Conservative publication candidate <= 200 Hz for low-frequency signaling |
| Application note | Outputs are voltage outputs, not dry contacts. Use an external relay if dry-contact behavior or higher-power switching is required. |
| Power | |
| Input | 12-24VDC |
| Derived input current @ 12 VDC | Approximately 70 to 100 mA, excluding external output loads |
| Derived input current @ 24 VDC | Approximately 35 to 50 mA, excluding external output loads |
| Additional current per asserted DI | Approximately 2.8 mA @ 12 VDC, 5.8 mA @ 24 VDC when driven from the module supply domain |
| Connectors | |
| Input | 1x4 plug-in screw terminal block |
| Output | 1x8 plug-in screw terminal block |
| Power | 1x2 plug-in screw terminal block |
| Terminal pitch | 3.5 mm |
| Leds | |
| Output | 8 blue |
| Input | 4 blue |
| System | 1-
2-Emergency |
| Software | |
| Connection | TCP |
| Interface | IPIO Manager |
| UAC | Username/Password [1] |
| General | |
| Dimensions | 110x83x30 mm (without rail adaptor) |
| Weight | 202 g |
| Package | Cardboard box (13x18x8 cm) |
| Mounting | DIN-Rail mount |
| Certification | CE, Rohs |
Notes